The how and why of EIFS moisture inspections,
EIFS (sometimes referred to as "synthetic stucco" had
its beginning in Europe at the end of Word War II, and
quickly became popular as a building material because
of its ease of installation and cost efficiency. It was
introduced to the U.S. market in 1969 but was not widely
used as a construction material until the 1980's. It
was first used in commercial applications, and became
popular as a residential construction material.
Today EIFS buildings account for approximately 17% of
the commercial market and approximately 3.5% of the residential
market. The first company to manufacture EIFS in the
United States was the Dryvit company, which is why EIFS
is sometimes referred to as "Dryvit".
The acronym "EIFS" stands for Exterior Insulated Finishing
System. EIFS is a non-load bearing exterior wall finishing
system that gives the building a stucco like appearance.
The system consists of four components:
- Panels of expanded polystyrene foam insulation glued
or screwed to the substrate or vapor barrier.
- A base coat that is troweled over the foam insulation
panels.
- A glass fiber reinforcing mesh that is laid over
the polystyrene insulation panels and fully embedded
in the base coat and.
- A finish coat that is troweled over the base coat
and the reinforcing mesh. The base coat, mesh and finish
coat are usually 1 / 8 to 1 / 4 inches thick. This
is also called the lamina.
There are two basic types of EIFS currently in use in
the U.S., barrier and water-managed. Barrier EIFS is
designed to divert all water from the exterior surface.
Water-managed EIFS anticipates that some water will penetrate
the surface and incorporates redundant water-management
features (flashing, weeping, drainage plane and waterdurable
substrates) to ensure that water that breaches the exterior
finish will quickly exit the system. Most EIFS clad homes
in the U.S. are barrier EIFS systems.
The advantage of EIFS as a finishing system is that
it is energy efficient and economical to install. Unfortunately,
barrier EIFS systems have been found to have problems,
often serious, with moisture intrusion. In 1995, building
inspectors in Wilmington, North Carolina discovered
severe moisture damage on hundreds of EIFS clad homes
in that area. Similar problems have since been discovered
on EIFS clad homes in other parts of the country, resulting
in a class action lawsuit against the EIFS manufacturers.
In some cases, removal of the EIFS cladding has revealed
extensive water damage to the framing, jeopardizing the
building's structural integrity.
Because the EIFS system is watertight, water that penetrates
behind the EIFS sheathing does not readily evaporate.
The barrier EIFS system is designed to allow for small
amounts of water vapor, but the system does not allow
larger amounts of water to readily evaporate. Water can
become trapped and can soak into the substrate and framing.
Unlike more traditional facades, there is normally no
secondary barrier (house wrap) installed behind the EIFS
to protect the sheathing or framing. Severe damage could
occur without any exterior signs. These problems can
exist regardless of the age of the building or the quality
of construction. Some of our inspections have revealed
extensive damage to buildings' substrate and framing,
of which the homeowners were completely unaware. If problem
areas are identified, preventative measures can be taken
before damage occurs, or before it becomes extensive
enough to jeopardize the structural integrity of the
building. Early detection and prevention of moisture
intrusion can save thousands of dollars in repairs later
on.
Water does not usually enter through the EIFS system
itself, but through penetrations in the EIFS. The most
common areas of moisture intrusion are around windows
and doors, at the intersections between the EIFS and
the roof, and areas where the EIFS has been penetrated
by attachments such as mailboxes, shutters, decorative
molding, railings, deck attachments, vents, chimney caps
over EIFS clad chimneys, and utility lines and pipes.
Proper attachment of penetrations is essential to prevent
water intrusion. EIFS systems also depend heavily on
sealant (caulking) to keep moisture from getting behind
the system. If the sealant is decayed, damaged or missing,
water intrusion may occur. Moisture intrusion may also
occur if the EIFS is cracked or damaged.
An EIFS inspection is intended to identify areas of
high moisture content in the sheathing and framing, to
identify areas where the substrate has already been damaged
by water, and to identify areas of potential moisture
intrusion. Often, an EIFS inspection will detect leaks
that are not related to the EIFS system at all. For example,
our inspectors have located roof leaks and leaks from
shower enclosures during EIFS inspections.
There are standard inspection protocols governing EIFS
inspections, but each building must be evaluated independently.
The nature and scope of the inspection may change according
to what is discovered. The inspection may take several
hours, and may even span more than one day. Before the
inspection the buyer, homeowner, or other client is asked
to complete a survey detailing what specific areas of
concern should be addressed, any problems that have been
seen, and other information about the building. When
the EIFS inspection occurs as a result of a real estate
transfer, the EIFS inspector should coordinate with the
home inspector and the termite inspector to share information
and findings. After the inspection, a customized report
is prepared for the homeowner or client, including recommendations
about maintaining an EIFS building to minimize the risk
of water damage.
In a standard EIFS inspection a non-intrusive moisture
scanner is used to identify relatively high moisture
content. In areas where the scanner indicates a high
moisture content a probe moisture meter is inserted to
test for the moisture content of the substrate and to
test for damage to the substrate. The probe moisture
meter is also used at random locations throughout the
system, and in areas where potential moisture intrusion
commonly occurs, such as near windows. A high moisture
content in the probe reading indicates that water intrusion
has occurred, and may be causing structural damage to
the building. If the probe indicates that the substrate
is soft, this could be a sign that damage has already
occurred. The probe moisture meter will make small holes
in the EIFS, which are then sealed by the inspector with
an industry-approved sealant.
If the probe moisture meter indicates high moisture
content, or if areas of soft substrate are found, it
may be necessary or advisable to conduct an invasive
inspection. This will involve removing sections of the
EIFS to physically inspect the substrate or framing.
Sometimes significant damage is discovered, which, if
not repaired, could jeopardize the building's structural
integrity. The invasive inspection also allows the inspector
to examine the building for insects.
Regular inspections of EIFS buildings are recommended
by the industry to mi8nimize the risk of serious damage
and to identify potential problems before they become
serious. Be sure to utilize the services of a qualified
and trained EIFS inspector. |